实用老年医学 ›› 2024, Vol. 38 ›› Issue (8): 792-796.doi: 10.3969/j.issn.1003-9198.2024.08.009

• 临床研究 • 上一篇    下一篇

320排探测器自由呼吸冠状动脉CT血管造影在老年病人中应用的可行性和临床价值

王璇, 唐无量, 邵海磊, 徐秋贞   

  1. 210048 江苏省南京市,东南大学附属中大医院江北院区医学影像科
  • 收稿日期:2023-09-15 出版日期:2024-08-20 发布日期:2024-08-26
  • 通讯作者: 徐秋贞,Email:xuqiuzhen831@sina.com
  • 基金资助:
    江苏省医学会伦琴影像科研专项资金项目[SYH-3201150-0009(2021004)]

Feasibility and application value of free-breathing coronary CT angiography using 320-MDCT in elderly patients

WANG Xuan, TANG Wuliang, SHAO Hailei, XU Qiuzhen   

  1. Department of Medical Imaging, Jiangbei Branch of Zhongda Hospital Affiliated Southeast University, Nanjing 210048, China
  • Received:2023-09-15 Online:2024-08-20 Published:2024-08-26
  • Contact: XU Qiuzhen, Email:xuqiuzhen831@sina.com

摘要: 目的 探讨使用320排探测器CT在老年病人自由呼吸状态下进行冠状动脉成像(CCTA)检查的可行性和临床价值。方法 回顾性选取2022年10月至2023年5月在东南大学附属中大医院使用320排探测器CT进行CCTA扫描的老年病人100例,根据扫描时呼吸状态分为自由呼吸组和屏息组,每组50例。测量2组主动脉(aorta)、右主干(RCA)、左主干(LM)的CT值、信噪比(SNR)、对比噪声比(CNR)和冠周脂肪组织的标准差(SD)、有效剂量(ED)并比较。两名医师采用4分法对2组冠状动脉15分段的图像质量进行双盲评分并比较,使用Kappa检验评估两位医师主观评分的一致性。结果 2组主动脉、RCA、LM的CT值、SNR和CNR差异均无统计学意义(P>0.05)。2组的主观评分以及高心率(>75次/min)与中低心率(≤75次/min)的主观评分差异均无统计学意义(P>0.05),两位医师的主观评分一致性较好(Kappa值为0.633和0.720),自由呼吸组的ED小于屏息组(P<0.05)。结论 老年病人使用320排探测器CT行自由呼吸CCTA具有可行性,可以在较低的辐射剂量下获得较高的图像质量。

关键词: 320排探测器, 自由呼吸, 冠状动脉CT血管造影

Abstract: Objective To explore the feasibility and application value of 320-Multi-Detector CT(320-MDCT) for free-breathing coronary CT angiography (CCTA) in the elderly patients. Methods A total of 100 elderly patients who underwent CCTA scanning using 320-MDCT at Zhongda Hospital Southeast University from October 2022 to May 2023 were selected retrospectively. The patients were divided into free-breathing group (n=50) and breath-holding group (n=50) based on their respiratory status during the scan. The CT values, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) of the aorta, right coronary artery (RCA) and left main coronary artery (LM) and effective dose (ED), standard deviation (SD) of pericoronal adipose tissue in the two sets of images were measured and compared. Two physicians used a 4-point method to perform a double-blind evaluation of the image quality of 15 coronary segments in the two groups, and Mann-Whitney U test was used to evaluate the subjective ratings. Kappa test was used to assess inter-rater agreement of the two physicians. Results The differences in CT values, SNR and CNR of aorta, RCA and LM between the two groups were not statistically significant (P>0.05).There was no significant difference in subjective scores between the two groups and the same results were observed in the high heart rate group (>75 bpm) and the medium-low heart rate group (≤75 bpm) (P >0.05). The consistency of subjective scores between the two physicians was good (kappa values were 0.633 and 0.720), and the level of ED in the free-breathing group was lower than that in the breath-holding group (P <0.05). Conclusions Free-breathing CCTA may be feasible on 320-MDCT with high image quality and low radiation dose in the elderly patients.

Key words: 320-MDCT, free-breathing, coronary CT angiography

中图分类号: